164 research outputs found

    Adaptive Finite Element Simulation of Currents at Microelectrodes to a Guaranteed Accuracy. Application to Channel Microband Electrodes.

    Get PDF
    We extend our earlier work (see K. Harriman et al., Technical Report NA99/19) on adaptive finite element methods for disc electrodes to the case of reaction mechanisms to the increasingly popular channel microband electrode configuration. We use the standard Galerkin finite element method for the diffusion-dominated (low-flow) case, and the streamline diffusion finite element method for the convection-dominated (high-flow) case. We first consider the simple E reaction mechanism (convection-diffusion equation) and we demonstrate excellent agreement with previous approximate analytical results across the range of parameters of interest, on comparatively coarse meshes. We then consider ECE and EC2E reaction mechanisms (linear and nonlinear systems of reaction-convection-diffusion equations, respectively); again we are able to demonstrate excellent agreement with previous results.\ud \ud The authors are pleased to acknowledge the financial support of the following organisations: a research studentship for KH; a Career Development Fellowship from the Medical Research Council for DJG, which has allowed them to undertake this research

    Hierarchical Bayesian inference for ion channel screening dose-response data

    Get PDF
    Dose-response (or 'concentration-effect') relationships commonly occur in biological and pharmacological systems and are well characterised by Hill curves. These curves are described by an equation with two parameters: the inhibitory concentration 50% (IC50); and the Hill coefficient. Typically just the 'best fit' parameter values are reported in the literature. Here we introduce a Python-based software tool, PyHillFit , and describe the underlying Bayesian inference methods that it uses, to infer probability distributions for these parameters as well as the level of experimental observation noise. The tool also allows for hierarchical fitting, characterising the effect of inter-experiment variability. We demonstrate the use of the tool on a recently published dataset on multiple ion channel inhibition by multiple drug compounds. We compare the maximum likelihood, Bayesian and hierarchical Bayesian approaches. We then show how uncertainty in dose-response inputs can be characterised and propagated into a cardiac action potential simulation to give a probability distribution on model outputs

    Early afterdepolarisation tendency as a simulated pro-arrhythmic risk indicator

    Get PDF
    Drug-induced Torsades de Pointes (TdP) arrhythmia is of major interest in predictive toxicology. Drugs which cause TdP block the hERG cardiac potassium channel. However, not all drugs that block hERG cause TdP. As such, further understanding of the mechanistic route to TdP is needed. Early afterdepolarisations (EADs) are a cell-level phenomenon in which the membrane of a cardiac cell depolarises a second time before repolarisation, and EADs are seen in hearts during TdP. Therefore, we propose a method of predicting TdP using induced EADs combined with multiple ion channel block in simulations using biophysically-based mathematical models of human ventricular cell electrophysiology. EADs were induced in cardiac action potential models using interventions based on diseases that are known to cause EADs, including: increasing the conduction of the L-type calcium channel, decreasing the conduction of the hERG channel, and shifting the inactivation curve of the fast sodium channel. The threshold of intervention that was required to cause an EAD was used to classify drugs into clinical risk categories. The metric that used L-type calcium induced EADs was the most accurate of the EAD metrics at classifying drugs into the correct risk categories, and increased in accuracy when combined with action potential duration measurements. The EAD metrics were all more accurate than hERG block alone, but not as predictive as simpler measures such as simulated action potential duration. This may be because different routes to EADs represent risk well for different patient subgroups, something that is difficult to assess at present

    Gaussian process emulation for discontinuous response surfaces with applications for cardiac electrophysiology models

    Get PDF
    Mathematical models of biological systems are beginning to be used for safety-critical applications, where large numbers of repeated model evaluations are required to perform uncertainty quantification and sensitivity analysis. Most of these models are nonlinear both in variables and parameters/inputs which has two consequences. First, analytic solutions are rarely available so repeated evaluation of these models by numerically solving differential equations incurs a significant computational burden. Second, many models undergo bifurcations in behaviour as parameters are varied. As a result, simulation outputs often contain discontinuities as we change parameter values and move through parameter/input space. Statistical emulators such as Gaussian processes are frequently used to reduce the computational cost of uncertainty quantification, but discontinuities render a standard Gaussian process emulation approach unsuitable as these emulators assume a smooth and continuous response to changes in parameter values. In this article, we propose a novel two-step method for building a Gaussian Process emulator for models with discontinuous response surfaces. We first use a Gaussian Process classifier to detect boundaries of discontinuities and then constrain the Gaussian Process emulation of the response surface within these boundaries. We introduce a novel `certainty metric' to guide active learning for a multi-class probabilistic classifier. We apply the new classifier to simulations of drug action on a cardiac electrophysiology model, to propagate our uncertainty in a drug's action through to predictions of changes to the cardiac action potential. The proposed two-step active learning method significantly reduces the computational cost of emulating models that undergo multiple bifurcations

    Rapid Characterization of hERG Channel Kinetics I: Using an Automated High-Throughput System

    Get PDF
    Predicting how pharmaceuticals may affect heart rhythm is a crucial step in drug-development, and requires a deep understanding of a compound’s action on ion channels. In vitro hERG-channel current recordings are an important step in evaluating the pro-arrhythmic potential of small molecules, and are now routinely performed using automated high-throughput patch clamp platforms. These machines can execute traditional voltage clamp protocols aimed at specific gating processes, but the array of protocols needed to fully characterise a current is typically too long to be applied in a single cell. Shorter high-information protocols have recently been introduced which have this capability, but they are not typically compatible with high-throughput platforms. We present a new 15 second protocol to characterise hERG (Kv11.1) kinetics, suitable for both manual and high-throughput systems. We demonstrate its use on the Nanion SyncroPatch 384PE, a 384 well automated patch clamp platform, by applying it to CHO cells stably expressing hERG1a. From these recordings we construct 124 cell-specific variants/parameterisations of a hERG model at 25C. A further 8 independent protocols are run in each cell, and are used to validate the model predictions. We then combine the experimental recordings using a hierarchical Bayesian model, which we use to quantify the uncertainty in the model parameters, and their variability from cell to cell, which we use to suggest reasons for the variability. This study demonstrates a robust method to measure and quantify uncertainty, and shows that it is possible and practical to use high-throughput systems to capture full hERG channel kinetics quantitatively and rapidly

    Reproducible model development in the Cardiac Electrophysiology Web Lab

    Get PDF
    The modelling of the electrophysiology of cardiac cells is one of the most mature areas of systems biology. This extended concentration of research effort brings with it new challenges, foremost among which is that of choosing which of these models is most suitable for addressing a particular scientific question. In a previous paper, we presented our initial work in developing an online resource for the characterisation and comparison of electrophysiological cell models in a wide range of experimental scenarios. In that work, we described how we had developed a novel protocol language that allowed us to separate the details of the mathematical model (the majority of cardiac cell models take the form of ordinary differential equations) from the experimental protocol being simulated. We developed a fully-open online repository (which we termed the Cardiac Electrophysiology Web Lab) which allows users to store and compare the results of applying the same experimental protocol to competing models. In the current paper we describe the most recent and planned extensions of this work, focused on supporting the process of model building from experimental data. We outline the necessary work to develop a machine-readable language to describe the process of inferring parameters from wet lab datasets, and illustrate our approach through a detailed example of fitting a model of the hERG channel using experimental data. We conclude by discussing the future challenges in making further progress in this domain towards our goal of facilitating a fully reproducible approach to the development of cardiac cell models

    Importance of modelling hERG binding in predicting drug-induced action potential prolongations for drug safety assessment

    Get PDF
    Reduction of the rapid delayed rectifier potassium current (IKr) via drug binding to the human Ether-Ă -go-go-Related Gene (hERG) channel is a well recognised mechanism that can contribute to an increased risk of Torsades de Pointes. Mathematical models have been created to replicate the effects of channel blockers, such as reducing the ionic conductance of the channel. Here, we study the impact of including state-dependent drug binding in a mathematical model of hERG when translating hERG inhibition to action potential changes. We show that the difference in action potential predictions when modelling drug binding of hERG using a state-dependent model versus a conductance scaling model depends not only on the properties of the drug and whether the experiment achieves steady state, but also on the experimental protocols. Furthermore, through exploring the model parameter space, we demonstrate that the state-dependent model and the conductance scaling model generally predict different action potential prolongations and are not interchangeable, while at high binding and unbinding rates, the conductance scaling model tends to predict shorter action potential prolongations. Finally, we observe that the difference in simulated action potentials between the models is determined by the binding and unbinding rate, rather than the trapping mechanism. This study demonstrates the importance of modelling drug binding and highlights the need for improved understanding of drug trapping which can have implications for the uses in drug safety assessment

    Models of the cardiac L-type calcium current: A quantitative review

    Get PDF
    The L-type calcium current (ICaL) plays a critical role in cardiac electrophysiology, and models of ICaL are vital tools to predict arrhythmogenicity of drugs and mutations. Five decades of measuring and modeling ICaL have resulted in several competing theories (encoded in mathematical equations). However, the introduction of new models has not typically been accompanied by a data-driven critical comparison with previous work, so that it is unclear which model is best suited for any particular application. In this review, we describe and compare 73 published mammalian ICaL models and use simulated experiments to show that there is a large variability in their predictions, which is not substantially diminished when grouping by species or other categories. We provide model code for 60 models, list major data sources, and discuss experimental and modeling work that will be required to reduce this huge list of competing theories and ultimately develop a community consensus model of ICaL. // This article is categorized under: Cardiovascular Diseases > Computational Models Cardiovascular Diseases > Molecular and Cellular Physiolog

    Accounting for variability in ion current recordings using a mathematical model of artefacts in voltage-clamp experiments

    Get PDF
    Mathematical models of ion channels, which constitute indispensable components of action potential models, are commonly constructed by fitting to whole-cell patch-clamp data. In a previous study, we fitted cell-specific models to hERG1a (Kv11.1) recordings simultaneously measured using an automated high-throughput system, and studied cell-cell variability by inspecting the resulting model parameters. However, the origin of the observed variability was not identified. Here, we study the source of variability by constructing a model that describes not just ion current dynamics, but the entire voltage-clamp experiment. The experimental artefact components of the model include: series resistance, membrane and pipette capacitance, voltage offsets, imperfect compensations made by the amplifier for these phenomena, and leak current. In this model, variability in the observations can be explained by either cell properties, measurement artefacts, or both. Remarkably, by assuming that variability arises exclusively from measurement artefacts, it is possible to explain a larger amount of the observed variability than when assuming cell-specific ion current kinetics. This assumption also leads to a smaller number of model parameters. This result suggests that most of the observed variability in patch-clamp data measured under the same conditions is caused by experimental artefacts, and hence can be compensated for in post-processing by using our model for the patch-clamp experiment. This study has implications for the question of the extent to which cell-cell variability in ion channel kinetics exists, and opens up routes for better correction of artefacts in patch-clamp data. This article is part of the theme issue 'Uncertainty quantification in cardiac and cardiovascular modelling and simulation'
    • …
    corecore